Asset ID: |
1-71-1315501.1 |
Update Date: | 2018-05-10 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1315501.1
:
How to Replace a Sun Fire X4140 CPU
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire X4140 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4140 CPU.
Solution
CAP PROBLEM OVERVIEW: Replace a X4140 Processor
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Familiarity or training for X4470 platform
TASK COMPLEXITY: 3
TIME ESTIMATE: 60 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Power off the server.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Preparing for Servicing Processor
1.1 Disconnect power cord(s) from the power supply(ies)
1.2 Slide server out of rack
1.3 Attach an antistatic wrist strap
When servicing or removing server components, attach antistatic strap to your wrist and then to a metal area on chassis
1.4 Remove top cover
2. Removing Processor
2.1 Identify which processor remove : Processor 0 is closest to PSU bay
2.2 Unscrew the two heatsink screws
2.3 Twist heatsink slightly to break seal with grease, and then lift off heatsink
2.4 Disengage lever by pushing down and moving to side, then rotating upward
2.5 Open pressure frame
2.6 Remove processor
2.7 Place removed processor in anti-static package
3. Installing Processor
3.1 Clean off old thermal interface material from heatsink and processor, using supplied alcohol wipe
3.2 Set heat sink aside
3.3 Place new processor in socket.Make sure orientation is correct
3.4 Lower pressure plate. Make sure pressure plate sits flat around periphery of processor.
3.5 Engage the lever by rotating downward and slipping under the catch
3.6 Using supplied grease syringe, empty syringe on to processor in star shaped pattern
3.7 Smooth grease into thin even layer on top of processor
3.8 Orient heatsink so that two screws line up with mounting studs
If XOption Processor : Tighten screws alternately one 1/2 turn until fully seated
3.9 Tighten screws alternately one-half turn until fully seated
4. Return Server to Operation
4.1 Install top cover
4.2 Install server into rack
4.3 Reconnect power cord(s) to the power suppl(ies). Verify AC Present LED is lit
4.4 Power on the server
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4140 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x4140/820-2401-14/index.html
Attachments
This solution has no attachment