Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1315328.1
Update Date:2018-05-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1315328.1 :   How to Replace a Sun Fire X4140, X4240 Power Distribution Board Cable  


Related Items
  • Sun Fire X4140 Server
  •  
  • Sun Fire X4240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire X4240 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire X4140 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4140, X4240 Power Distribution Board Cable.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4140, X4240 Training

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4140, X4240 Power Distribution Board Cable needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Sys-admin required to shut the system down

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Take necessary precautions to avoid ESD.

1. Remove PDB Cable
Power off the server.
Disconnect the power cord (or cords) from the power supply (or supplies).
Slide the server out of the rack.
Remove the top cover.
Remove the air duct.
Remove the PDB end of the cable.
Release the locking latches on either side and then pull the cable straight up.
Grasp each end of the connector on the motherboard, and then pull straight up to disconnect from the connector.
Remove a PDB Cable
2. Install replacement PDB Cable
Inspect the motherboard pin field to ensure all pins are straight
Open the locking latches on the PDB connector.
Ensure the key of the cable lines up with the slot on the connector.
Push the cable connector into the PDB connection until it is seated.
The latches should be above the connector housing.
Carefully align the motherboard connector to the motherboard pin field.
Gently press the connector down until it is seated. If you feel significant resistance, stop and check the pin alignment.
Replace the air duct.
Return the server to operation.
Install the top cover.
Slide the server into the rack.
Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
Power on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
sys-admin required to bring the system back online.

PARTS NOTE:

N/A

REFERENCE INFORMATION:

X4140/X4240 Service Manuals http://download.oracle.com/docs/cd/E19121-01/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback