Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1315298.1
Update Date:2018-05-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1315298.1 :   How to Replace a Sun Fire X4240 CPU  


Related Items
  • Sun Fire X4240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: CAP

Applies to:

Sun Fire X4240 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4240 CPU.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4240 Training

TIME ESTIMATE: 90 minutes

TASK COMPLEXITY: 3

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4240 CPU needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Power off the server.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Preparing for Servicing Processor

1.1 Disconnect power cord(s) from the power supply(ies)

1.2 Slide server out of rack

1.3 Attach an antistatic wrist strap

When servicing or removing server components, attach antistatic strap to your wrist and then to a metal area on chassis

1.4 Remove top cover

2. Removing Processor

2.1 Identify which processor remove : Processor 0 is closest to PSU bay. If it's a faulty processor, press the remind button

2.2 Unscrew the two heatsink screws

2.3 Twist heatsink slightly to break seal with grease, and then lift off heatsink

2.4 Disengage lever by pushing down and moving to side, then rotating upward

2.5 Open pressure frame

2.6 Remove processor

2.7 Place removed processor in anti-static package

3. Installing Processor

3.1 Clean off old thermal interface material from heatsink and processor, using supplied alcohol wipe

3.2 Set heat sink aside

3.3 Place new processor in socket.Make sure orientation is correct

3.4 Lower pressure plate. Make sure pressure plate sits flat around periphery of processor.

3.5 Engage the lever by rotating downward and slipping under the catch

3.6 Using supplied grease syringe, empty syringe on to processor in star shaped pattern

3.7 Smooth grease into thin even layer on top of processor

3.8 Orient heatsink so that two screws line up with mounting studs

3.9 Tighten screws alternately one 1/2 turn until fully seated

4. Return Server to Operation

4.1 Install top cover

4.2 Install server into rack

4.3 Reconnect power cord(s) to the power suppl(ies). Verify AC Present LED is lit

4.4 Power on the server

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Restart system and have the System administrator verify functionality of system.

PARTS NOTE:

REFERENCE INFORMATION:

Sun Fire X4240 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x4240/820-3835-14/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback