Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1315273.1
Update Date:2018-05-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1315273.1 :   How to Replace a Sun Fire X4240 Light Pipe Assembly  


Related Items
  • Sun Fire X4240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: CAP

Applies to:

Sun Fire X4240 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4240 Light Pipe Assembly.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4240 Training

TIME ESTIMATE: 75 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4240 Light Pipe Assembly needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Then power down the system and disconnect the Power Cord.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Removing the Front Control Panel Light Pipe Assembly
1. Remove the hard drive cage .
2. Remove the hard drive backplane .
3. Remove the three No. 2 Phillips screws securing the front control panel light pipe assembly to the hard drive cage.
4. Slide the light pipe assembly out of the hard drive cage.

Installing the Front Control Panel Light Pipe Assembly
1. Align the light pipe assembly with the mounting holes on the hard drive cage.
2. Secure the light pipe assembly with three No. 2 Phillips screws.
3. Install the hard drive backplane .
4. Install the hard drive cage .

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:Caution - Never attempt to run the server with the covers removed. Hazardous voltage is present.

REFERENCE INFORMATION:

Sun Fire X4240 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/sf.x4240/820-3835-14/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback