Asset ID: |
1-71-1313805.1 |
Update Date: | 2018-05-17 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1313805.1
:
How to Replace a Sun Fire X4600, X4600 M2 HDD
Related Items |
- Sun Fire X4600 M2 Server
- Sun Fire X4600 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Applies to:
Sun Fire X4600 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire X4600 M2 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4600, X4600 M2 HDD.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 45 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4600, X4600 M2 HDD needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The BIOS RAID utility or Operating System should be configured by the customer such that the disk drive is free for replacement.
E.g. The disk may be part of BIOS RAID configuration, Volume Management software, mounted file-system, raw partitions, etc.
A data backup is recommended as a precaution and may be required to restore data onto a replaced disk.
Orderly shutdown of applications and OS may be required if the disk being replaced is the boot device and no mirroring is in place. Customer will need to restore/recover from backup
NOTE: If the system has less than 4 x HDDs, filler panels must be present in the empty drive slots to ensure proper cooling.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Locate the hard disk drive to be replaced by viewing the LED on the front of the drives. If middle LED is amber, this indicates the drive is faulty
2. Ensure the correct hard disk drive is being replaced and label if necessary. Press the button on the front to release the spring loaded lever.
3. Grasp the handle and remove the drive from the bay
4. Open the latch of the replacement hard disk drive and insert into the bay
5. Push the drive into the bay until it stops. Close the spring loaded lever handle to engage the hard disk drive to the hard disk backplane
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Customer to verify drive availability
Customer to use appropriate software commands to re-activate/re-sync mirror if manual intervention is required
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire x4600 and Sun Fire x4600 M2 Server Service Manuals
http://download.oracle.com/docs/cd/E19121-01/
Detailed SVM instructions can be found at
http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html
See Document 1010946.1 for Detailed Veritas Volume Manager instructions.
See Document 1002753.1 for Detailed ZFS instructions
OTube video: https://otube.oracle.com/media/How+to+Remove+and+Replace+a+Sun+Fire+X4600++X4600+M2+Hard+Disk+Drive/0_c1htcs13
References
<NOTE:778.1> - Troubleshooting Video Issues in MOS
<NOTE:1002753.1> - How to Replace a Drive in Solaris[TM] ZFS
<NOTE:1010946.1> - General Guidance for Diagnosis (Disk Failures/Errors) and Replacing Internal Server Disks and JBOD Disks within Solaris
Attachments
This solution has no attachment