SANtricity - How to Remove and Replace Midrange Disk 6x80 PCU:ATR:2394:2
Related Items |
- Sun Storage 6580 Array
- Sun Storage 6780 Array
- Sun Storage Flexline 380 Array
- Sun Storage 6540 Array
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: CAP
Applies to:
Sun Storage 6780 Array - Version Not Applicable and later
Sun Storage Flexline 380 Array - Version Not Applicable and later
Sun Storage 6580 Array - Version Not Applicable and later
Sun Storage 6540 Array - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and replace Midrange Disk 6x80 PCU SANtricity
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Has gone through basic 2500/6000 Array Hardware Introduction
SANtricity
TIME ESTIMATE: 10 minutes
TASK COMPLEXITY: 2
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: FLX380/6540/6580/6780 Controller Tray PCU has been identified as faulty.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Array should be powered up and online, and the management host available for reference and access to the Recovery Guru.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Before beginning the repair procedure below, deactivate ASR temporarily so that additional Service Requests are not created.
After completing the repair procedure, reactivate ASR. Refer to <Document 1508403.1> ASR Deactivation / Reactivation via My Oracle Support.
1. The PCU is on the non-cabled side of the controller tray
2. Use both levers to release and pull the power supply assembly from the control module chassis.
3. Slide the new power supply assembly into the control module chassis and firmly push it until the latches snap into place.
4. Wait approximately 60 seconds for the storage management software to recognize the new power supply assembly
5. The Green power LED should now be "On".
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
1. Verify That no critical faults exist on the system
2. If applies, reactivate ASR.