Asset ID: |
1-71-1312946.1 |
Update Date: | 2017-03-22 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1312946.1
:
SANtricity - How to Remove and Replace Midrange Disk CSM200 Power Cooling Unit (PCU):ATR:2381:2
Related Items |
- Sun Storage 6180 Array
- Sun Storage 6580 Array
- Sun Storage Flexline 280 Array
- Sun Storage 6780 Array
- Sun Storage B280 Array
- Sun Storage Flexline 380 Array
- Sun Storage 6540 Array
- Sun Storage D240 (STK) Array
- Sun Storage D280 Disk Subsystem
- Sun Storage Flexline 240 Array
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Storage D280 Disk Subsystem - Version Not Applicable and later
Sun Storage 6180 Array - Version Not Applicable and later
Sun Storage 6580 Array - Version Not Applicable and later
Sun Storage 6780 Array - Version Not Applicable and later
Sun Storage Flexline 280 Array - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace Midrange Disk CSM200 Power Cooling unit (PCU) in SANtricity
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Has gone through basic 2500/6000 Array Hardware Introduction
SANtricity
TIME ESTIMATE: 15 minutes
TASK COMPLEXITY: 2
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: CSM200 PCU has been identified as faulty.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
NOTE: Please make sure that the PCU part is second edition p/n 300-2319
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Before beginning the repair procedure below, deactivate ASR temporarily so that additional Service Requests are not created.
After completing the repair procedure, reactivate ASR. Refer to <Document 1508403.1> ASR Deactivation / Reactivation via My Oracle Support.
1. Push the power switch on the failed power-fan assembly to the "Off" position.
2. Unplug the power cord from the failed power-fan assembly.
3. If power-fan assembly "A" is being replaced lift the latch/handle up to unlock the power-fan assembly and pull the power-fan assembly out of the tray. If power-fan assembly "B" is being replaced pull the latch/handle down to unlock the power-fan assembly and pull the power-fan assembly out of the tray.
4. Insert the new power supply
5. Plug the power cord into the new PCU
6. Turn the power switch to the ON position
7. The Green power LED should be On
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
1. Verify That no critical faults exist on the system
2. If applies, reactivate ASR.
PARTS NOTE:
REFERENCE INFORMATION: The Service Advisor in CAM
NOTE: If the service advisor is not available, you may download or review a soft copy internally at:
http://pts-storage.us.oracle.com/products/CAM/SA.html
Attachments