Asset ID: |
1-71-1312899.1 |
Update Date: | 2018-04-18 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1312899.1
:
SANtricity - How to Remove and Replace Midrange Disk CSM100 Power Supply Unit:ATR:2376:2
Related Items |
- Sun Storage 6580 Array
- Sun Storage Flexline 280 Array
- Sun Storage 6780 Array
- Sun Storage 6140 Array
- Sun Storage Flexline 210 Array
- Sun Storage B280 Array
- Sun Storage Flexline 380 Array
- Sun Storage D240 (STK) Array
- Sun Storage 6540 Array
- Sun Storage Flexline 240 Array
- Sun Storage D280 Disk Subsystem
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Storage Flexline 210 Array - Version Not Applicable and later
Sun Storage Flexline 280 Array - Version Not Applicable and later
Sun Storage D240 (STK) Array - Version Not Applicable and later
Sun Storage 6540 Array - Version Not Applicable and later
Sun Storage Flexline 240 Array - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace a CSM100 Power Supply Unit in SANtricity
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Has gone through basic 2500/6000 Array Hardware Introduction
SANtricity
TIME ESTIMATE: 15 minutes
TASK COMPLEXITY: 2
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: CSM100/FLA200/FLC200/FLA300 Power Supply has been identified as faulty.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Before beginning the repair procedure below, deactivate ASR temporarily so that additional Service Requests are not created.
After completing the repair procedure, reactivate ASR. Refer to <Document 1508403.1> ASR Deactivation / Reactivation via My Oracle Support.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Turn the power switch on the failed power supply to the "Off" position.
2. Unplug the power cord from the failed power supply.
3. Squeeze the pull ring on the failed power supply to release the lever. Open the lever, and pull the power supply out of the unit.
4. Insert the new power supply.
5. Plug the power cord back into the supply
6. Switch the power to ON position.
7. Green LED should be lit.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
1. Verify That no critical faults exist on the system
2. If applies, reactivate ASR.