Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1312795.1
Update Date:2017-10-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1312795.1 :   How to Replace and Remove a Ultra Enterprise 3500/4500/5500/6500 Keyswitch Assy:ATR:1490:1  


Related Items
  • Sun Enterprise 3500 Server
  •  
  • Sun Enterprise 5000 Server
  •  
  • Sun Enterprise 3000 Server
  •  
  • Sun Enterprise 4000 Server
  •  
  • Sun Enterprise 5500 Server
  •  
  • Sun Enterprise 6000 Server
  •  
  • Sun Enterprise 6500 Server
  •  
  • Sun Enterprise 4500 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun Enterprise 5500 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Sun Enterprise 6000 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 6500 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 3000 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 3500 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Information in this document applies to any platform.

Goal

******************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1312795.1
******************************************************************************


How to Replace and Remove a Ultra Enterprise 3500/4500/5500/6500 Keyswitch Assy

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Basic Sun hardware FE skills

- TIME ESTIMATE: 60 minutes

- TASK COMPLEXITY: 1


FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:
Replace the Keyswitch Assembly

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software system shutdown and power off.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace the Keyswitch assembly.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.

PARTS NOTE:
None

REFERENCE INFORMATION:
Refer to the Sun System Handbook for the FRU overview (P/N 370-1810)

E3000 Reference
E3500 Reference
E4000/5000/6000 Reference
E4500/5500/6500 Reference