Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1312771.1
Update Date:2017-10-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1312771.1 :   How to Replace and Remove a Ultra Enterprise 3500/4500/5500/6500 Clock Board:ATR:1142:1  


Related Items
  • Sun Enterprise 3500 Server
  •  
  • Sun Enterprise 5000 Server
  •  
  • Sun Enterprise 3000 Server
  •  
  • Sun Enterprise 4000 Server
  •  
  • Sun Enterprise 5500 Server
  •  
  • Sun Enterprise 4500 Server
  •  
  • Sun Enterprise 6000 Server
  •  
  • Sun Enterprise 6500 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun Enterprise 3000 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Sun Enterprise 3500 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 4000 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 4500 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 5000 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Information in this document applies to any platform.

Goal

******************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1312771.1
******************************************************************************


How to Replace and Remove a Ultra Enterprise 3500/4500/5500/6500 Clock Board

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.

- TIME ESTIMATE: 15 minutes

- TASK COMPLEXITY: 1



FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:
How to replace a Clock board

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software and system shutdown.
System power off is required.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
*** Follow standard ESD procedures to avoid Electrostatic Discharge

1. Unfasten cable connectors from the clock+ board front panel and set them aside

2. Loosen the two captive screws securing the board to the system chassis

3. Pull the ends of both extraction levers outward simultaneously to release the board from the centerplane receptacles

4. If you are replacing the clock+ board, remove the TOD NVRAM from the old board and place it on the new board.
*** This is necessary to match the host ID with the Ethernet ID.

5. Use the extraction levers to seat the replacement board.
Simultaneously swing both levers into the locked position. Do not press on board front panel to seat it---doing so will damage the connector pins.

6. Secure the board to the chassis using the two captive screws, one on each side

7. Connect any applicable interface cables to the front panel of the board

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify the green led is lit on the clock board.

Boot the system and start the applications.

PARTS NOTE:
None

REFERENCE INFORMATION:

E3000 Reference
E3500 Reference
E4000/5000/6000 Reference
E4500/5500/6500 Reference


Attachments