Solution Type Technical Instruction Sure Solution 1312748.1 : How to Replace and Remove a Ultra Enterprise 3500/4500/5500/6500 SCSI Ethernet Card
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Sun Enterprise 5500 Server - Version Not Applicable to Not Applicable [Release N/A]Sun Enterprise 3000 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Enterprise 3500 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Enterprise 4000 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Enterprise 4500 Server - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. Goal****************************************************************************** FixDISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner. TIME ESTIMATE: 30 minutes TASK COMPLEXITY: 1
DELIVERY REQUIREMENT: Schedule for immediate replacement within contractual terms.
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software and system shutdown. System power off is required.
For on-board ethernet connector failure, please refer to the Mother Board replacement action plan.
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: *** Follow standard ESD procedures to avoid Electrostatic Discharge
1. Identify the slot of the SBus card to be replaced.
2. The system could be mounted in a rack, so it will be necessary to use some tools to unmount it
3. Release the IO board containing the failing SBus from the system card cage
4. SBUS: Remove the 2 screws that secure the SBus card to the back panel
4. SBUS: SBus cards are locked by Nylon standoffs, so they need to be unlocked by pulling up the tips of the 2 standoffs
5. SBUS: Carefully lift the SBus card from the socket at an angle while guiding the face plate out from the back panel opening. The connector housing may break if the SBus card is tilted too far
6. SBUS: In order to install the new SBus card, remove the black plastic card retainer shipped with the card.
7. Carefully insert the SBus card into the socket. Pins could be bent if both connectors are not well aligned
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
PARTS NOTE: None