Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1312745.1
Update Date:2017-10-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1312745.1 :   How to Replace a Ultra Enterprise 3500/4500/5500/6500 Tape Drive:ATR:1590:1  


Related Items
  • Sun Enterprise 5000 Server
  •  
  • Sun Enterprise 3500 Server
  •  
  • Sun Enterprise 3000 Server
  •  
  • Sun Enterprise 4000 Server
  •  
  • Sun Enterprise 5500 Server
  •  
  • Sun Enterprise 4500 Server
  •  
  • Sun Enterprise 6000 Server
  •  
  • Sun Enterprise 6500 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun Enterprise 5000 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Sun Enterprise 5500 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 4500 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 3000 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Sun Enterprise 6000 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Information in this document applies to any platform.

Goal

******************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1312745.1
******************************************************************************


How to Remove and Replace a Ultra Enterprise 3500/4500/5500/6500 Tape Drive

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.

- TIME ESTIMATE: 60 minutes

- TASK COMPLEXITY: 1


FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:
How to replace a Tape Drive

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software and system shutdown.
System power off is required.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Ensure system is shut down

2. Remove front bezel

3. Loosen media tray/retention screws and remove tape drive.

4. Remove tape drive

5. Install replacement tape drive (ensure new drive's SCSI ID is set to "5")

6. Replace front bezel

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

See chapter 8 of p/n 805-2632-10( 6500/5500/4500 Systems Reference Manual )