Asset ID: |
1-71-1312469.1 |
Update Date: | 2017-10-18 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1312469.1
:
How to Replace and Remove an Ultra Enterprise 3000/3500/4000/4500/5000/5500/6000/6500 Frame Buffer:ATR:1587:1
Related Items |
- Sun Enterprise 3500 Server
- Sun Enterprise 5000 Server
- Sun Enterprise 3000 Server
- Sun Enterprise 4000 Server
- Sun Enterprise 5500 Server
- Sun Enterprise 6000 Server
- Sun Enterprise 6500 Server
- Sun Enterprise 4500 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Enterprise 6000 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Enterprise 5500 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Enterprise 6500 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Enterprise 3000 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Enterprise 3500 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Replace and Remove an Ultra Enterprise 3x00/4x00/5x00/6x00 Frame Buffer
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 1
DELIVERY REQUIREMENT:
Schedule for immediate replacement within contractual terms.
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software and system shutdown.
System power off is required.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Ensure system is shut down
2. Locate IO board containing faulty frame buffer
3. Remove IO board
4. Replace frame buffer card. Beware of connector damage during this process.
5. Insert IO board into system
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
E3000 Reference manual at http://download.oracle.com/docs/cd/E19095-01/ent35.srvr/802-6051-11/802-6051-11.pdf
E3500 Reference manual at http://docs.oracle.com/cd/E19095-01/ent35.srvr/805-2630-11/805-2630-11.pdf
E4000/5000/6000 Reference manual at http://download.oracle.com/docs/cd/E19095-01/ent35.srvr/802-3845-11/802-3845-11.pdf
E4500/5500/6500 Reference manual at http://download.oracle.com/docs/cd/E19095-01/ent35.srvr/805-2632-11/805-2632-11.pdf
Attachments
This solution has no attachment