![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1310870.1 : How to Replace and Remove an Ultra Enterprise 3500/4500/5500/6500 SBus Card:ATR:1129:1
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers
Applies to:Sun Enterprise 5000 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun Enterprise 5500 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Enterprise 6000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Enterprise 4500 Server - Version: Not Applicable and later [Release: N/A and later] Sun Enterprise 3000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Information in this document applies to any platform. GoalHow to Replace and Remove an Ultra Enterprise 3500/4500/5500/6500 SBus CardSolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner. - TIME ESTIMATE: 30 minutes - TASK COMPLEXITY: 1 FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: How to replace a SBus card WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : The customer should conduct an orderly software and system shutdown. System power off is required. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: *** Follow standard ESD procedures to avoid Electrostatic Discharge 1. Identify the slot of the sbus card to be replaced. 2. The system could be mounted in a rack, so it will be necessary to use some tools to umount it 3. Release the IO board containing the failing sbus from the system card cage 4. Remove the 2 screws that secure the SBus card to the back panel 4. SBus cards are locked by Nylon standoffs, so they need to be unlocked by pulling up the tips of the 2 standoffs 5. Carefully lift the SBus card from the socket at an angle while guiding the face plate out from the back panel opening. The connector housing may break if the SBus card is tilted too far 6. In order to install the new SBus card, remove the black plastic card retainer shipped with the card. 7. Carefully insert the SBus card into the socket. Pins could be bent if both connectors are not well aligned OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: If the sbus replaced was an Ethernet card, then verify the network connectivity If the sbus replaced was a Fiber or SCSI card, then verify that all the disks are well recognized, and synchronize any disabled disk (via SVM or VxVM). PARTS NOTE: The IO+ board has 3 SBus card locations The Graphics+ IO board has 2 SBus card locations REFERENCE INFORMATION: E3000 Reference E3500 Reference E4000/5000/6000 Reference E4500/5500/6500 Reference Attachments This solution has no attachment |
||||||||||||
|