Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1310863.1
Update Date:2016-03-31
Keywords:

Solution Type  Technical Instruction Sure

Solution  1310863.1 :   How to remove and replace M4000 M5000 Power Cord:ATR:1150:0  


Related Items
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

How to remove and replace M4000 M5000 Power Cord
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1310863.1
********************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure

TASK COMPLEXITY: 0

TIME ESTIMATE: 15 minutes

REMOVAL/REPLACEMENT INSTRUCTIONS:

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a prerequisite but is a wise precaution.

Power supply redundancy only exists when running all power supplies with 230VAC input power.
If the system is running on 110VAC input power, the customer does need to shutdown the system before replacing a power cord.
If the system is running on 230VAC input power, as long as the system has its minimum number of power supplies connected to input power and providing power to the system, the customer does not need to shutdown the system before replacing a power cord.


WHAT ACTIONS ARE REQUIRED?:

1. Identify which power cord you will replace.
    The power inlets are numbered from 0 on the right hand side when viewed from the rear.
    The power supplies are numbered from 0 on the left hand side when viewed from the front
2. Disconnect the power cord from the power inlet that you are replacing
3. Install replacement power cord

WHAT ACTION ARE NEEDED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Check PSU LEDs to show that replaced power cord is functioning.
Check the output of the command "showlogs -r -M monitor" , and wait for the "Power recovery completed" message.
This is what you should see when replacing the AC power cord for PSU3:

Nov 17 14:54:50 m5000-tvp540-xscf monitor_msg: SCF:Power failure (/PSU#3)
Nov 17 14:55:18 m5000-tvp540-xscf monitor_msg: SCF:Power recovery start(/PSU#3)
Nov 17 14:55:42 m5000-tvp540-xscf monitor_msg: SCF:Power recovery complete(/PSU#3)

PARTS NOTE:

REFERENCE INFORMATION:
Service Manual: http://download.oracle.com/docs/cd/E19855-01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.