Solution Type Technical Instruction Sure Solution 1310671.1 : How to remove and replace a Starcat Fan Backplane:ATR:1544:4
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers
Applies to:Sun Fire E25K Server - Version: Not ApplicableSun Fire 12K Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire 15K Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire E20K Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalHow to remove and replace a Starcat Fan BackplaneSolutionCAP PROBLEM OVERVIEW: Fan backplane to be replaced.DISPATCH INSTRUCTIONS WHAT SKILLS DOES THE ENGINEER NEED: Starcat training, familiarity with SMS command set TASK COMPLEXITY: 4 TIME ESTIMATE: 240 minutes DELIVERY REQUIREMENT: This procedure requires an extended outage on all domains, to be negotiated with the customer during contract hours. TASK COMPLEXITY: 4 FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : 1. Ensure SC failover is enabled and all data in in sync ("showfailover; showdatasync"). 2. All domains should be shut down to the OBP ("ok prompt"). WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Powering Off a Fan Backplane
Removing a Fan Backplane
Installing a Fan Backplane
Powering On a Fan Backplane
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Power-on domains. Note: If multiple domains are started simultaneously, this will cause a slower POST times. PARTS NOTE: Consult service manual for part locations and diagrams. REFERENCE INFORMATION: Service Manual: http://download.oracle.com/docs/cd/E19065-01/servers.e25k/index.html Attachments This solution has no attachment |
||||||||||||
|