Solution Type Technical Instruction Sure Solution 1310628.1 : How to Remove and Replace a Starcat Tape Drive:ATR:1537:2
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers
Applies to:Sun Fire 12K Server - Version: Not ApplicableSun Fire 15K Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire E25K Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire E20K Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalHow to remove and replace a Starcat Tape DriveSolutionCAP PROBLEM OVERVIEW: System controller tape drive needs replacement.DISPATCH INSTRUCTIONS WHAT SKILLS DOES THE ENGINEER NEED: Starcat Training, Familiarity with SMS command set TIME ESTIMATE: 30 minutes FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Customer should fail-over to the OTHER SC and disable SMS failover Preparation: Note: Before shutting down and replacing an SC make sure that clock from the other SC to all components is in a good state. To check this run "showboards -c" command for SMS 1.4 and later. ( See *Document ID: 1006413.1 Check clock status before replacement of System controller for more information ) As user sms-svc (or another user with platform privileges), verify: - that the other SC is MAIN (showfailover -r) - that the other SC is the current clock source (showboards -c) - that failover is disabled (showfailover) - shut down SC with faulty drive ("init 0"), then power it off from the main using "poweroff scX" Physical Replacement: - Unseat the SC board. SCs have been known to automatically power on, which can cause problems during this procedure. - Remove the SC Peripheral board (the tape drive and DVD drive are externally visible here). - Replace the tape drive - IMPORTANT: Insert the SCPER board FIRST, then insert the SC board LAST. Poweron spare SC: - "poweron scX" - Observe boot sequence, ensure no errors appear - Wait for SMS to start, then enable failover "setfailover on" OBTAIN CUSTOMER ACCEPTANCE: N/A WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: N/A REFERENCE INFORMATION: Service Manual: http://download.oracle.com/docs/cd/E19065-01/servers.e25k/index.html Attachments This solution has no attachment |
||||||||||||
|