![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1310596.1 : How to remove and replace a Starcat PCI Cassette:ATR:1532:2
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers
Applies to:Sun Fire 12K Server - Version: Not ApplicableSun Fire E20K Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire 15K Server - Version: Not Applicable and later [Release: N/A and later] Sun Fire E25K Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalHow to remove and replace a Starcat PCI CassetteSolutionCAP PROBLEM OVERVIEW: PCI Cassette FailureDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Starcat Training TASK COMPLEXITY: 2 TIME ESTIMATE: 30 minutes FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. The customer is not required to perform a system shutdown. Someone with root access is required to properly unconfigure/configure the card per instruction below. Customer should study the possibility of replacement by DR: Verify for each I/O adapter being detached that an alternate path to system critical resources on another I/O board exists. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: DR: DR Detach: NOTE: Pulling cassette without properly disconnecting from Solaris may cause domain to panic if doing an active replacement. Ensure that the adapter in the cassette to be removed has terminated all input/output operations# cfgadm -v -c disconnect AP-ID Wait for the amber removal indicator LED to illuminate Label and remove the I/O cables from the cassette. Remove and replace PCI Cassette Insert the PCI cassette into the appropriate slot (C5V0, C3V0, C3V1, or C3V2) Reconnect the I/O cables to the cassette. DR Attach: # cfgadm -v -c configure AP-ID No DR: Shut down Domain Power off Domain Remove and replace PCI Cassette Power on domain and Hpost lavel 32 Start the domain OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Check status of PCI card and multi-path software PARTS NOTE: N/A REFERENCE INFORMATION: Service Manual: http://download.oracle.com/docs/cd/E19065-01/servers.e25k/index.html Attachments This solution has no attachment |
||||||||||||
|