Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1310579.1
Update Date:2018-05-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1310579.1 :   How to Remove and Replace a Starcat Crypto Card:ATR:1529:2  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
  • Sun Fire E20K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun Fire E25K Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire E20K Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire 12K Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Fire 15K Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

How to remove and replace a Starcat Crypto Card

Solution

CAP PROBLEM OVERVIEW: Crypto Card Failure

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Starcat Training

TASK COMPLEXITY: 2

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Study the possibility of replacement by DR:

Verify for each I/O adapter being detached that an alternate path to system critical resources on another
I/O board exists.

cfgadm -avl
dual path?

multi-path software (IPMP, mpxio, dmp, SVM, VM etc.)

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

DR:

DR Detach:

Ensure that the adapter in the cassette to be removed has terminated all
input/output operations

cfgadm -v -c disconnect AP-ID

Wait for the amber or blue removal indicator LED to illuminate

Label and remove the I/O cables from the cassette.

Remove PCI Cassette

Replace Crypto Card following service manual procedure.

Insert the PCI cassette into the appropriate slot (C5V0, C3V0, C3V1, or C3V2)

Reconnect the I/O cables to the cassette.

DR Attach:

cfgadm -v -c configure AP-ID

No DR:

Shut down Domain

Power off Domain

Replace Crypto Card following service manual procedure.

Power on domain and Hpost lavel 32

Start the domain

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Check status of Crypto card and multi-path software

PARTS NOTE:

N/A

REFERENCE INFORMATION:
Service Manual: http://download.oracle.com/docs/cd/E19065-01/servers.e25k/index.html

TIME ESTIMATE: 120 minutes