Asset ID: |
1-71-1310491.1 |
Update Date: | 2018-05-09 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310491.1
:
How to Replace a Sun Fire X4150, X4250 Power Supply
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4150 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4150, X4250 Power Supply.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Basic Sun hardware FE skills, familiarity or training for X4450 platform.
TIME ESTIMATE: 15 minutes.
DELIVERY REQUIREMENT:
Schedule with maintenance window within contractual terms.
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Server has two power supply redundancy. The server can remain running if replacing only one power supply. If, not Customer should shut the operating system down gracefully (using "init 0").
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Identify which power supply you will replace.
2. Disconnect the power cord from the power supply that you are replacing. The power supplies are hot-swappable, so you do not have to shut down the server or disconnect the second power supply.
3. Remove the power supply.
4. Installation is the reverse of this procedure.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.
PARTS NOTE: N/A
REFERENCE INFORMATION: DocID=820-1852 Server Service Manual
http://download.oracle.com/docs/cd/E19121-01/
Sun Fire X4150, X4250, and X4450 Servers Diagnostics Guide
http://download.oracle.com/docs/cd/E19150-01/
http://download.oracle.com/docs/cd/E19121-01/
Attachments
This solution has no attachment