Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1310469.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1310469.1 :   How to Replace a V245 Disk Backplane:ATR:1271:1  


Related Items
  • Sun Fire V245 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Sun Fire V245 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to replace a V245 Disk Backplane

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
V245 product knowledge/training to be qualified as Oracle service personel.

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 1

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW:
Disk Backplane is faulty.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution
Customer should conduct an orderly software system shutdown
Power down System & disconnect Power Cords

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedures to avoid Electrostatic Discharge
1. Power off the system
2. Remove the optional DVD super-multi drive from the chassis (if installed).
3. Remove all hard drives from the chassis.
Note - Identify the slot in which each hard drive belongs for later installation into
the chassis.
4. Remove the upper and lower cable retainers
5. Disconnect the motherboard/SAS backplane cable from the hard drive
backplane
6. Remove the three screws that secure the hard drive backplane
to the hard drive card cage assembly
7. Remove the hard drive backplane from the chassis and place it on an antistatic matt.
8. Unpackage the replacement hard drive backplane and place it on an antistatic
mat.
9. Use three screws to attach the hard drive backplane to the hard
drive cage assembly
Note - Do not tighten the screws until all three of them are in place.
10. Reinstall the DVD super-multi drive (if necessary).
11. Connect the motherboard/SAS backplane cable to the replacement hard drive
backplane.
12. If necessary, connect the motherboard/SAS backplane cable to the DVD supermulti
drive.
13. Install the upper and lower cable retainers
14. Reinstall all hard drives in the slots from which you removed them.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot the system and start the application as per the sys admin procedure

PARTS NOTE:

https://mosemp.us.oracle.com/handbook_internal/Systems/SunFireV245/components.html#DiskBackplane



REFERENCE INFORMATION:

Sun Fire V215 and V245 Servers Service Manual



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback