Goal
How to replace a V245 Rack Mount Kit
Solution
*DISPATCH INSTRUCTIONS*
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
- TIME ESTIMATE: 60 minutes
- TASK COMPLEXITY: 0
*REMOVAL/REPLACEMENT INSTRUCTIONS*
PROBLEM OVERVIEW:
Faulty rack mount kit
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
WHAT ACTIONS ARE REQUIRED:
1. Powering off the system
2. Disconnect all the cables and power cords from the server
3. Extend the server to the maintenance position
4. Press the metal lever that is located on the inner side of the rail to disconnect the cable management
arm(CMA) from the rail assembly
5. From the front of the server, pull the release tabs forward and pull the server forward until it is free of the
rack rails
6. Remove mounting brackets(right side and left side) from the server
7. Attach new mounting bracket(right side and left side) into the server
8. Insert the ends of the the mounting brackets into the slide rails
9. Insert the new PCI card into the slot
10.Slide the chassis into the rack
11.Connect all the cables and power cords from the server
12.Powering on the system
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireV245/components.html#Rack
https://support.oracle.com/handbook_private/Systems/SunFireV215/components.html#Rack
REFERENCE INFORMATION:
Service Manual.
http://download.oracle.com/docs/cd/E19088-01/