1310447.1
:
How to Replace a V215/V245 Indicator Board Assembly:ATR:1266:1
Related Items |
- Sun Fire V215 Server
- Sun Fire V245 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Fire V245 Server - Version Not Applicable and later
Sun Fire V215 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a V215/V245 Indicator Board Assy
Solution
*DISPATCH INSTRUCTIONS*
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 1
*FIELD ENGINEER INSTRUCTIONS*
PROBLEM OVERVIEW:
Faulty Indicator Board needs replacement.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server
2. Remove the rear cover
3. Remove the front bezel after unfastening the bezel's securing screw
4. Remove the front cover.
5. Remove the two screws that secure the front indicator board to the chassis
6. Remove the front indicator board.
Slide the board to the right to disconnect it from the front I/O board.
7. Place front indicator board on an antistatic mat.
8. Installation is the reverse of this procedure
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot and check for full functionality.
PARTS NOTE:
V215
https://mosemp.us.oracle.com/handbook_internal/Systems/SunFireV215/components.html#Miscellaneous
V245
https://mosemp.us.oracle.com/handbook_internal/Systems/SunFireV245/components.html#Miscellaneous
REFERENCE INFORMATION:
Sun Fire V215 and V245 Servers Service Manual
Attachments
This solution has no attachment