How to Replace a Sun Fire X4150, X4250 Fan Module [VCAP]
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Applies to:
Sun Fire X4150 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4150, X4250 Fan Module.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) No special skills required, Customer Replaceable Unit (CRU) procedure
TASK COMPLEXITY: 0
TIME ESTIMATE: 15 minutes.
DELIVERY REQUIREMENT:
Schedule with maintenance window within contractual terms.
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Seven pairs of fan modules are located under the top cover door, providing N+1 cooling redundancy. Each fan module contains two fans mounted in an integrated, hot-swappable CRU.
If a fan module fails, replace the fan module as soon as possible to maintain server availability.
Fan modules are hot-swappable and can be removed and installed while the server is running without affecting the rest of the server's capabilities.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing a Fan Module
1. Extend the server into the maintenance position.
2. Unlatch the fan module door.
3. Identify the faulty fan module with a corresponding Service Required LED.
4. Using thumb and forefinger in between the two fans, pull the fan module up and out of the connector.
Installing a Fan Module
1. With the top cover door open, install the replacement fan module into the server (FIGURE 3-9).
2. Apply firm pressure to fully seat the fan module.
3. Verify that the Fan Fault LED on the replaced fan module is not lit.
4. Close the top cover door.
5. Verify that the Top Fan LED, Service Required LEDs, and the Locator LED/Locator button are not lit.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.
PARTS NOTE: N/A
REFERENCE INFORMATION: DocID=820-1852 Server Service Manual