Goal

How to replace a V215/V245 Power Supply

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 20 minutes

TASK COMPLEXITY: 0


*REMOVAL/REPLACEMENT INSTRUCTIONS*

PROBLEM OVERVIEW:
Faulty power supply

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The Sun Fire V245 server’s standard redundant hot-swappable power supplies enable you to remove and replace a power supply without shutting the server down, provided that the other power supply is online and working.
Note - An optional redundant, hot-swappable power supply is available for the Sun Fire V215 server.

WHAT ACTIONS ARE REQUIRED:

Note - An optional redundant, hot-swappable power supply is available for the Sun Fire V215 server.

The following indicators are lit when a power supply fault is detected:

- Front and rear Service Required indicators

- Rear PS Failure indicator on the bezel of the server

- Failure indicator on the faulty power supply

If a power supply fails and you do not have a replacement available, leave the failed power supply installed to ensure proper air flow in the server.

 

Removing a Power Supply

1. Identify which power supply(0 or 1) requires replacement


2. Gain access to the rear of the server where the faulty power supply is located

3. Release the cable management arm(CMA) - if installed

The CMA is located at the rear of the server rack.
- Press and hold the tab
- Rotate the CMA out of the way so that you can access the power supply

4. Disconnect the power cord from the faulty power supply

5. Grasp the power supply handle and move the power supply latch to the right

6. Pull the power supply out of the chassis

Installing a Power Supply

1. Align the replacement power supply with the empty power supply chassis bay

2. Slide the power supply into the bay until it is fully seated

9. Reconnect the power cord to the power supply

3. Close the CMA, inserting the end of the CMA into the rear left rail bracket

4. Verify that the Failure indicator on the replaced power supply, the Service Required indicator,
and the front and rear Service Required indicator are not lit

5 .At the sc> prompt, type the showenvironment command to verify the status of the power supplies

PARTS DETAILS:

Sun Fire V215

https://support.oracle.com/handbook_private/Systems/SunFireV215/components.html#Power

Sun Fire V245

https://support.oracle.com/handbook_private/Systems/SunFireV245/components.html#Power



REFERENCE INFORMATION:

Service Manual.

V215/V245 Service Manual:  http://docs.oracle.com/cd/E19088-01/v215.srvr/819-3038-11/index.html