Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1310409.1
Update Date:2018-05-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1310409.1 :   How to Replace a Sun Fire X4150, X4250 PCI Card  


Related Items
  • Sun Fire X4150 Server
  •  
  • Sun Fire X4250 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X4150 Server - Version Not Applicable and later
Sun Fire X4250 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4150, X4250 PCI Card.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 45 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4150, X4250 PCI Card needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Data backup not required but recommended as a precaution
Orderly shutdown of applications
Shutdown of OS and power down of server

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Ensure standard ESD procedures are followed

1. Power off the server and unplug (REMOVE) the power cords
2. Remove the top cover
3. Locate the PCI card to be replaced
4. Label cables and disconnect from existing PCI card
5. Remove the back panel crossbar by loosening the captive screws at each end and lifting the crossbar up and back to remove it
6. Loosen the captive screw on the end of the riser. Remove the riser and the PCI card attached to it as a whole
5. Carefully remove the PCI card from the riser connector
6. Install the replacement PCI card into the riser connector
7. Re-install the riser card by sliding it back until it sits in the slot in the back panel and tighten the captive screw
8. Re-install the crossbar and tighten the captive screws
9. Re-connect the cables previously removed from the PCI card
8. Replace the top cover
9. Re-attach the power cords

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify access to the new PCI card

PARTS NOTE:

REFERENCE INFORMATION:
Sun Fire 4150 Server Service Manual -
http://download.oracle.com/docs/cd/E19121-01/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback