Asset ID: |
1-71-1310390.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310390.1
:
How to replace a V245 Disk Fan Tray:ATR:1257:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V245 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a V245 Disk Fan Tray
Solution
*DISPATCH INSTRUCTIONS*
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
- TIME ESTIMATE: 15 minutes
- TASK COMPLEXITY: 0
*REMOVAL/REPLACEMENT INSTRUCTIONS*
PROBLEM OVERVIEW:
Faulty Disk Fan Tray
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer is not required to perform a system shutdown.
WHAT ACTIONS ARE REQUIRED:
1. Open the disk fan tray access door
2. Verify that the fan tray is faulty
A lit Fan Fault indicator on the top of a fan tray indicates that the fan tray is faulty
Note ! The hard drive fan tray has two fans
3. Pull up on the fan tray handle and remove the fan tray from the chassis
4. Insert the new fan tray
5. Confirm that the new fan tray is working. The LED should not be lit
6. Close the fan tray door
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check FAN LEDs
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireV245/components.html#Fan
REFERENCE INFORMATION:
Service Manual.
http://download.oracle.com/docs/cd/E19088-01/
Attachments
This solution has no attachment