Goal
450 Floppy Disk Replacement
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
SE450 product knowledge/training to be qualified as Oracle service personel.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
Floppy Diskette Drive Failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord. Then Remove the Right Side Panel, Avoid Electrostatic Discharge, Remove the Disk Fan Tray Assembly and Remove the Removable Media Assembly.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1) Remove a Floppy Diskette Drive
1. Place the removable media assembly on a table.
2. Remove the four Phillips screws that secure the drive to its mounting bracket.
3. Disconnect the SCSI drive data cable from the back of the drive.
4. Disconnect the SCSI drive power cable from the rear of the drive.
5. Push on the rear of the drive and, holding the drive's face plate, slide the drive out of the bay.
2) Install a Floppy Diskette Drive
1. Remove the filler panel from the drive bay, if necessary.
2. If you are installing a full-height drive, remove the divider that separates the upper and lower drive bays in the removable media assembly.
3. If you have removed a full-height drive and are installing one or more half-height drives, you must replace the divider.
4. Slide the drive part way into its bay in the removable media assembly.
5. Connect the SCSI data cable and power cable to the rear of the drive.
6. Fasten the four Phillips screws that secure the drive to its mounting bracket.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.