Asset ID: |
1-71-1310367.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310367.1
:
How to Remove and Replace a Sun Enterprise 450 Disk Backplane:ATR:1380:1
Related Items |
- Sun Enterprise 450 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Enterprise 450 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
450 Disk Backplane Replacement
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
E450 Product Training or Experience
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: Faulty Disk Backplane.
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord. Then Position the System for Service, Remove the Right Side Panel, Remove all Disk Drives from disk cage, Remove the Disk Fan Tray Assembly, Avoid Electrostatic Discharge.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removal:
1. Disconnect the 4-slot UltraSCSI data cable from the backplane at connector J0102.
Press the tabs on both sides of the connector to release the cable.
2. Disconnect the 4-slot UltraSCSI power cable from the backplane at connector
J0101.
Press the tab on the bottom of the connector to release the cable.
3. If your system is configured to include one or more 8-slot UltraSCSI backplanes,
disconnect the I2C cable at connector P0500.
Press the tab on top of the connector to release the cable.
4. Remove the two screws that secure the backplane to the disk cage.
Use a Phillips screwdriver.
5. Lift the backplane free from the five mounting hooks near the base of the disk
cage, and remove it from the system.
Place the backplane on an antistatic mat.
Installation:
1. Insert the 4-slot Ultra SCSI backplane down into the five mounting hooks near the
base of the disk cage.
Push down on the edge of the backplane only.
2. Fasten the two Phillips screws that secure the backplane to the disk cage.
3. If your system is configured to include one or more 8-slot UltraSCSI backplanes,
connect the I2C cable at connector P0500.
4. Connect the 4-slot UltraSCSI power cable to the backplane at connector J0101.
5. Connect the 4-slot UltraSCSI data cable to the 4-slot SCSI backplane at connector
J0102.
6. Install the Disk Fan Tray Assembly.
7. Install the Right Side Panel.
8. Install all Disk Drives you removed from the disk cage.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.
PARTS NOTE:
https://mosemp.us.oracle.com/handbook_internal/Systems/E450/components.html#SCSI
REFERENCE INFORMATION:
Ultra Enterprise 450 Server Owner's Guide
http://download.oracle.com/docs/cd/E19088-01/450.srvr/805-0429-10/805-0429-10.pdf
Attachments
This solution has no attachment