Asset ID: |
1-71-1310345.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310345.1
:
How to Remove and Replace a Sun Enterprise 450 Memory DIMM:ATR:1373:1
Related Items |
- Sun Enterprise 450 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Enterprise 450 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
450 Memory DIMM
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
SE450 product knowledge/training to be qualified as Oracle service personel.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: Memory/DIMM Failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution. The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord, remove the left side panel , avoid Electrostatic Discharge, and then Remove the CPU Fan Tray Assembly.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1) Remove a Memory Module
1. Locate on the main logic board the memory module that you want to remove.
2. Push the ejection lever away from the memory module to eject it from the socket.
3. Grasp both corners of the memory module and pull it out of the socket.
2) Install a Memory Module
1. Remove the new memory module from its antistatic packaging.
2. Locate the socket into which you will install the module.
3. Align the memory module with its socket so that the small notch on the corner of the module is on the same side as the lever.
4. Hold the bottom edge of the module parallel to its socket. Carefully align the module so that each of its gold edge contacts is centered on a socket pin.
5. Push firmly and evenly on both ends of the memory module until the bottom edge is firmly seated in the socket.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
Part location
https://mosemp.us.oracle.com/handbook_internal/Systems/E450/components.html#Memory
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19088-01/450.srvr/index.html
Attachments
This solution has no attachment