Asset ID: |
1-71-1310333.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310333.1
:
How to Remove and Replace a 450 CPU fan and/or Disk Fan Tray:ATR:1698:1
Related Items |
- Sun Enterprise 450 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Enterprise 450 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
Sun Enterprise 450 CPU fan tray assembly and/or Sun Enterprise 450 DISK fan tray assembly
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
SE450 product knowledge/training to be qualified as Oracle service personel.
TIME ESTIMATE: 50 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
CAP PROBLEM OVERVIEW: CPU fan or DISK fan
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord. Then Position the System for Service, Remove the System Cover, Avoid Electrostatic Discharge and Remove the Removable Media Assembly (RMA).
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
For the CPU Fan tray Assembly;
1) Remove CPU Fan Tray
1. Disconnect the CPU fan tray cable from the main logic board at connector J4704. Press the tab on the connector to release the cable.
2. Deflect the tab that secures the CPU fan tray in the guide on the bottom of the chassis, and slide the tray out of the chassis.
2) Install a CPU Fan Tray
1. Slide the CPU fan tray into the chassis. Align the CPU fan tray in the fan tray guides at the top and bottom of the chassis. Slide in the CPU fan tray until it locks into place.
2. Connect the CPU fan tray cable to the main logic board at connector J4704.
For the Disk Fan tray Assembly;
1) Remove a Disk Fan Tray Assembly
1. Disconnect the disk fan tray/interlock cable from the disk fan tray assembly. Press the tab on top of the connector to release the cable.
2. Slide any cables out of the clip attached to the disk fan tray assembly.
3. Deflect the tab that secures the tray in the guide at the bottom of the chassis, and slide the tray out of the system.
2) Install a Disk Fan Tray Assembly
1. Align the top edge of the disk fan tray assembly in the upper guide, and the bottom edge in the lower guide on the bottom of the chassis. It is easier to insert the disk fan tray when you insert the upper edge of the fan tray first.
2. Be sure that data cables are out of the way and slide the disk fan tray assembly into the chassis. The tab on the lower fan tray guide locks the assembly in place.
3. Slide any 8-slot UltraSCSI data cables into the clip attached to the disk fan tray assembly.
4. Connect the disk fan tray/interlock cable to the disk fan tray assembly. Make sure that the tab on the back of the connector locks in place.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
For more detail, refer to http://support.us.oracle.com/handbook_internal/Systems/E450/components.html
REFERENCE INFORMATION:
Refer to contents of corresponding product in System Handbook
http://docs.oracle.com/cd/E19088-01/450.srvr/805-0429-10/805-0429-10.pdf
Attachments
This solution has no attachment