Asset ID: |
1-71-1310300.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310300.1
:
How to Remove and Replace a PCI Card in a 450 Server:ATR:1370:1
Related Items |
- Sun Enterprise 450 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP
Applies to:
Sun Enterprise 450 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
450 PCI Card Replacement
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Nothing beyond basic product training.
TIME ESTIMATE: 50 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
PCI Card Failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord. Then Position the System for Service, Remove the System Cover, Avoid Electrostatic Discharge.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1) Remove a PCI Card
1. Disconnect all external cables from the faceplate of the PCI card.
2. Disconnect all cables connected to the internal connectors of the PCI card.
3. Remove the Phillips screw that secures the faceplate of the PCI card to the rear panel of the system.
4. Pull the PCI card all the way out of the slot.
5. Place the PCI card on an antistatic mat.
6. If you are not replacing the PCI card immediately, install a PCI filler panel.
2) Install a PCI Card
1. If you are installing a PCI card in an unused slot, remove the corresponding filler panel from the back of the system. Otherwise go to Step 2.
2. Insert the PCI card into the appropriate slot on the main logic board.
3. Secure the PCI card faceplate to the back panel with the Phillips screw.
4. If necessary, connect any internal cables to the PCI card's internal connectors.
5. If necessary, connect any external cables to the PCI card.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
Part location
https://mosemp.us.oracle.com/handbook_internal/Systems/E450/components.html
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19088-01/450.srvr/index.html