Goal
Solution


Applies to:

Sun Fire V445 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a Sun Fire V445 Power Supply

**************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1310134.1
**************************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
No specific skills required

TIME ESTIMATE: 15 Minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW:
Faulty power supply

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The system provides 2+2 redundancy, which means a completely loaded system can run with only 2 power supplies.  Power supplies are hot swappable which means they can be replaced on a running system without issuing a software command.  To avoid an unplanned outage always maintain at least 2 functioning power supplies.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. From the rear of the system, unlatch the cable management arm from the inner glide and move it
out of the way.
2. Disconnect the AC power cord from the power supply you want to remove.
3. Grasp the power supply by its handle and press the release latch with your thumb.
4. Slide the power supply out of the system.
5. Slide the power supply into its bay in the system.
6. Press the power supply firmly unit it latches into place.
7. Connect the AC power cord to the power supply.
8. Reattach the cable management arm to the inner glide.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:

Sun Fire V445 Server Service Manual is available here.