Asset ID: |
1-71-1310119.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310119.1
:
How to Replace a V445 XFP Card:ATR:1113:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V445 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace a Sun Fire V445 XFP Card
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Nothing beyond basic hardware skills.
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW:
Faulty XFP card
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a prerequisite but is a wise precaution
Customer should conduct an orderly software system shutdown
Power down System & disconnect Power Cords
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Identify the correct interface & Unplumb the interface using below command from OS
#ifconfig ce0 unplumb
2. Powering off the system
3. Remove the top cover
4. Disconnect any external cables attached to the faceplate of the XFP card.
5. Release the latch securing the XFP card to the chassis.
6. Pull the XFP card from its slot
7. Place the XFP card on an antistatic mat
8. Install the new XFP card into its slot
9. Rotate the latch down and secure it with the retaining pin.
10.If necessary, connect any external cables to the XFP card.
11.Install the top cover.
12.Power on the system
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot the system and start the application as per the sys admin procedure
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire V445 Server Service Manual.
http://download.oracle.com/docs/cd/E19088-01/
Attachments