Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1310117.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1310117.1 :   How to replace a V215/V245 PCI Card:ATR:1240:0  


Related Items
  • Sun Fire V215 Server
  •  
  • Sun Fire V245 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire V245 Server - Version Not Applicable and later
Sun Fire V215 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to replace a V215/V245 PCI Card

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

- TIME ESTIMATE: 30 minutes

- TASK COMPLEXITY: 0

*REMOVAL/REPLACEMENT INSTRUCTIONS*

PROBLEM OVERVIEW:
Faulty PCI card

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Then power down the system and disconnect the Power Cord.

WHAT ACTIONS ARE REQUIRED:

1. Powering off the system
2. Remove the rear cover
3. Remove the air baffle
4. Locate the PCI card that you want to remove
5. If necessary, make a note of where the PCI card is installed
6. Release the PCI hold-down bracket
7. Carefully remove the PCI card from the PCI card slot and riser board connector
8. Place the PCI card on an antistatic mat
9. Insert the new PCI card into the slot
10.Rotate the PCI hold-down bracket 90 degrees to lock the card in place
11.If a PCI long card is installed, use the brace from the air baffle to support the card
12.Install the rear cover.
13.Powering on the system

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Performing a reconfiguration boot if necessary to recognize the new PCI card.

PARTS NOTE:

Sun Fire V215

https://support.oracle.com/handbook_private/Systems/SunFireV215/components.html

Sun Fire V245

https://support.oracle.com/handbook_private/Systems/SunFireV245/components.html



REFERENCE INFORMATION:

Sun Fire V215/V245 Server Service Manual
http://download.oracle.com/docs/cd/E19088-01/



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.