Asset ID: |
1-71-1310109.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310109.1
:
How to Replace a V445 HBA Card:ATR:1108:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V445 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace a Sun Fire V445 HBA Card
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
No specific skills required
TIME ESTIMATE: 30 Minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW:
Faulty HBA Card
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server
2. Remove the main cover
3. Disconnect any external cables attached to the faceplate and any internal cables connected to the PCI card internal connectors
4. Release the latch securing the PCI card to the chassis and pull the pin forward and rotate the latch up and out of the way
5. Pull the PCI card from its slot
6. Place the PCI card on an antistatic mat
7. Installation is the reverse of this procedure
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot and check for full functionality
Changing a HBA with an embedded WWN may require SAN re-configuration
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire V445 Server Service Manual.
http://download.oracle.com/docs/cd/E19088-01/
Attachments
This solution has no attachment