Asset ID: |
1-71-1310101.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310101.1
:
How to replace a V245 XFP Card:ATR:1248:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V245 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a V245 XFP Card
Solution
*DISPATCH INSTRUCTIONS*
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0
*REMOVAL/REPLACEMENT INSTRUCTIONS*
PROBLEM OVERVIEW:
XFP card faulty
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution
Customer should conduct an orderly software system shutdown
Power down System & disconnect Power Cords
WHAT ACTIONS ARE REQUIRED:
1. Identify the correct interface & Unplumb the interface using below command from OS
#ifconfig ce0 unplumb
2. Powering off the system
3. Remove the top cover
4. Disconnect any external cables attached to the faceplate of the XFP card.
5. Release the latch securing the XFP card to the chassis.
6. Pull the XFP card from its slot
7. Place the XFP card on an antistatic mat
8. Install the new XFP card into its slot
9. Rotate the latch down and secure it with the retaining pin.
10.If necessary, connect any external cables to the XFP card.
11.Install the top cover.
12.Power on the system
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot the system and start the application as per the sys admin procedure
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireV245/components.html
REFERENCE INFORMATION:
Service Manual
http://docs.sun.com/app/docs/doc/819-3038-11
Attachments