Asset ID: |
1-71-1310054.1 |
Update Date: | 2018-05-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310054.1
:
How to remove and replace a Starcat System Controller - Center Plane Support Board Carrier Plate:ATR:1524:4
Related Items |
- Sun Fire E25K Server
- Sun Fire 12K Server
- Sun Fire 15K Server
- Sun Fire E20K Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun Fire E20K Server - Version Not Applicable and later
Sun Fire 12K Server - Version Not Applicable and later
Sun Fire 15K Server - Version Not Applicable and later
Sun Fire E25K Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace a Starcat System Controller - Center Plane Support Board Carrier Plat
Solution
CAP PROBLEM OVERVIEW: System Controller - Center Plane Support Board Carrier Plate Failure
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Starcat Training
TASK COMPLEXITY: 4
TIME ESTIMATE: 180 minutes
DELIVERY REQUIREMENT:
Immediate
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
N/A
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Note: Before shutting down and replacing an SC make sure that clock from the other SC to all components is in a good state. To check this run "showboards -c" command for SMS 1.4 and later. ( See Document ID: 1006413.1 - Check clock status before replacement of System controller for more information )
Note: FAB# 1000668.1 (The thermal utility should be run if a Centerplane or Center Plane Support Board is replaced on the Sun Fire 12K/15K/E20K/E25K)
For this replacement we use two procedures together from service manual:
1) Center plane Support Board Replacement Procedures
2) Carrier Plate Replacement for Standard Configuration
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check SC failover status
PARTS NOTE:
N/A
REFERENCE INFORMATION:
Service Manual: http://download.oracle.com/docs/cd/E19065-01/servers.e25k/index.html
References
<NOTE:1000668.1> - The thermcal utility should be run if a Centerplane or Centerplane Support Board (CSB) is replaced on the Sun Fire 12K/15K/E20K/E25K.
<NOTE:1006413.1> - Check Clock Status Before Replacement of System Controller
Attachments
This solution has no attachment