Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1309990.1
Update Date:2017-01-27
Keywords:

Solution Type  Technical Instruction Sure

Solution  1309990.1 :   How to Replace a T5120/T5220 or Netra T5220 PCIx, PCIe, or XAUI Card:ATR:1274:0 [VIDEO]  


Related Items
  • Sun SPARC Enterprise T5220 Server
  •  
  • Sun Netra T5220 Server
  •  
  • Sun SPARC Enterprise T5120 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  
  • _KM>Content>Video
  •  




Applies to:

Sun SPARC Enterprise T5220 Server - Version All Versions and later
Sun SPARC Enterprise T5120 Server - Version All Versions and later
Sun Netra T5220 Server - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a T5120/T5220 PCI Card
.

Video - ATR1274 (3:51)

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

Task Complexity: 0

REMOVAL/REPLACEMENT INSTRUCTIONS:

PROBLEM OVERVIEW:  PCIe/XAUI card failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
System needs to be shutdown by customer

WHAT ACTIONS ARE REQUIRED?:

Note - The Netra is configured with PCIx for slots 3 & 4.  All other PCI slots are PCIe.  The commercial servers do not use PCIx cards.

*** Follow standard ESD procedures to avoid Electrostatic Discharge

1. Power off the server
2. Disconnect all power cables
3. Disconnect any data cables connected to the PCI/XAUI card being serviced
4. Remove the Top Cover (On SPARC Enterprise)
  -Unlatch the fan module door by pulling the release tabs back to release the door
  -Press the top cover release button and slide the top cover to the rear about a 0.5 inch
  -Lift up and remove the cover
5. If not Netra PCI cards 3-5 go to step 8. 
6. Unloosen the screw to the PCI card edge lock(s), locate them away from the card, & then remove the failed card.
7. Insert the replacement card in appropriate location & then move the green PCI card edge arm(s) to support the edge away from the connector & tighten the locking screws.  Then reverse steps 4-1.
8. Remove the PCI cross beam on the SPARC Enterprise.  Loosen the two captive Phillips screws on each end of the removable PCI cross beam then slide the PCI cross beam back to remove it from the chassis.  On the Netra, remove the PCI Mezzanine. 
9. Loosen the captive screw securing the riser board to the motherboard
10. Remove the riser and the PCI/XAUI card attached to it as a unit
11. Carefully remove the PCI/XAUI card from the riser board connector
12. Place the PCI/XAUI card on an antistatic mat
13. Insert the new PCI/XAUI card into the riser board
14. After replacing reverse the order of fixing as mentioned in above points

NOTE: to verify functionality of the system:

1. Run the Solaris "fmadm faulty" and/or SP/ILOM "show faulty" command (run "showfaults -v" command if only ALOM is supported ) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Customer might need to consult the PCI/XAUI card specific manual for procedure to bring the card into operation

PARTS NOTES:

T5120:  https://support.oracle.com/handbook_private/Systems/SE_T5120/components.html

T5220:  https://support.oracle.com/handbook_private/Systems/SE_T5220/components.html

Netra T5220: https://support.oracle.com/handbook_private/Systems/Netra_T5220/components.html


REFERENCE INFORMATION: