Asset ID: |
1-71-1309981.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1309981.1
:
How to replace a V245 HBA Card:ATR:1244:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V245 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to replace a V245 HBA Card
Solution
*DISPATCH INSTRUCTIONS*
WHAT SKILLS ARE REQUIRED
No special skills required, Customer Replaceable Unit (CRU) procedure
- TIME ESTIMATE: 30 minutes
- TASK COMPLEXITY: 0
*REMOVAL/REPLACEMENT INSTRUCTIONS*
PROBLEM OVERVIEW:
Faulty HBA Card
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTIONS ARE REQUIRED:
1. Power off the server
2. Remove the rear cover
3. Disconnect any external cables attached to the faceplate and any internal cables connected to the PCI card internal connectors
4. Release the latch securing the PCI card to the chassis
5. Pull the PCI card from its slot
Removal of a long PCI card might require you to remove the air baffle
6. Place the PCI card on an antistatic mat
7. Installation is the reverse of this procedure
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot and check for full functionality
Changing a HBA with an embedded WWN may require SAN re-configuration
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireV245/components.html
REFERENCE INFORMATION:
Service Manual.
http://download.oracle.com/docs/cd/E19088-01/
Attachments