Asset ID: |
1-71-1309032.1 |
Update Date: | 2016-01-20 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1309032.1
:
How to Replace the Compact Flash Card for the Sun Blade X6450:ATR:2604:1
Related Items |
- Sun Blade 6000 System
- Sun Blade X6450 Server Module
- Sun Blade 6048 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential (INTERNAL). Do not distribute to customers.
Reason: FRU CAP
Applies to:
Sun Blade X6450 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace the Compact Flash Card for the Sun Blade X6450.
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field engineer.
DELIVERY REQUIREMENT:
As required by the customer.
TIME ESTIMATE: 60 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :Backup the data and power off the system.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. If necessary, back up any data that is contained on the compact flash (CF) card.
2. Power off the server and remove the server module from the chassis.
3. Remove the main cover, to remove the main cover you have to press down on the cover release button and, using the indent for leverage, slide the main cover toward the rear of the chassis approximately 0.5 inch (12 mm).
4. Locate the CF card under the RAID Expansion Module at the back of the server module
Note: The server module might not have a RAID Expansion Module, If the optional RAID Expansion Module is installed, you do not need to remove the RAID Expansion Module to remove the CF card.
5. Grasp the card, push down slightly, and pull card out.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restore the system, and safe the back up information.
PARTS NOTE:
NA
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19045-01/blade.x6450/index.html
Attachments
This solution has no attachment