Asset ID: |
1-71-1309008.1 |
Update Date: | 2018-05-18 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1309008.1
:
How to Replace a Sun Fire X4450 Coin Cell Battery
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4450 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4450 Coin Cell Battery.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4450 Coin Cell Battery needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Ensure standard ESD procedures are followed
1. Power off the server and disconnect (REMOVE) the power cords
2. Remove the main (top) cover|
3. Locate battery (behind PCI slots, PCI Riser Boards 2 & 5 will need to be removed) and remove by gently pulling the clip away from battery and lifting the battery straight up
4. Insert new battery with positive polarity facing chassis center
5. Replace main cover
6. Re-connect power cords
7. Reset the battery date & time.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.
PARTS NOTE:
Nil
REFERENCE INFORMATION:
Sun Fire X4450 Server Service Manual
http://download.oracle.com/docs/cd/E19150-01/
Sun Fire X4150, X4250, and X4450 Servers Diagnostics Guides
http://download.oracle.com/docs/cd/E19150-01/
http://download.oracle.com/docs/cd/E19121-01/
Attachments
This solution has no attachment