Solution Type  Technical Instruction Sure

Solution  1308704.1 :   Sun Fire V880 - V890 How to Replace a Faulty PCI IO Board:ATR:912:3  


Related Items
  • Sun Fire V880z Visualization Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire V890 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU CAP

Applies to:

Sun Fire V890 Server - Version Not Applicable and later
Sun Fire V880 Server - Version Not Applicable and later
Sun Fire V880z Visualization Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

******************************************************************************
To report errors or request improvements on this procedure,
please go to https://support.us.oracle.com and put a comment on Doc ID: 1308704.1
******************************************************************************

Solution

DISPATCH INSTRUCTIONS
- WHAT SKILLS DOES THE ENGINEER NEED:
Field training in Sun Fire V880/V890 Server

- TIME ESTIMATE: 60 min
- TASK COMPLEXITY:    3

FIELD ENGINEER INSTRUCTIONS:
- PROBLEM OVERVIEW:
Faulty PCI IO Board

- WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?:
A data backup is not a prerequisite but is a wise precaution
Customer should conduct an orderly software system shutdown
Power down System & disconnect Power Cords

- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedure

Note:
Use max post only when searching for IO Controller issues(max post does not add testing for PCI cards), Fatal Resets, and Unrecoverable Errors(UEs) that Solaris is unable to properly diagnose.  If diag-level is set to max at OBP, confirm with customer that if can be moved to the factory default of min.

See:  Guidance for POST Diagnostic Level Setting on Sun Fire[TM] 280R, V480, V490, V880, V890 and V880z servers. (Doc ID 1582330.1) for details.




Remove Side Door
Remove PCI Cards
Remove RSC Card
1. Disconnect AC power cords
Remove Fan Trays

Remove PCI Card Bracket
1. Remove PCI card dividers
2. Disconnect PCI status cable (P36) from I/O board
3. Remove screws securing PCI card bracket to chassis & I/O board stiffener
4. Remove PCI card bracket

Remove PCI I/O Board
1. Disconnect following cables from I/O board
   a. Narrow SCSI cable (P1) from connector J3403
   b. Ultra Wide SCSI cable (P1) from connector J3402
   c. I2C cable (P18) from connector J3805
   d. System status assembly cable (P32) from connector J3803
   e. Fan power cable from connectors J3804(P6), J3807(P10) and J3806(P3)
   f. Fan status cable (P28) from connector J3801
   g. I/O signal cable (P26) from connector J3201
   h. I/O board remote sense cable (P29) from connector J3202
   i. I/O board power cable (P14) from connector J3203
   j. PCI external status cable (P23) from connector J3601
2. Remove hex standoffs securing serial port plate
3. Remove back I/O plate from rear panel
4. Remove PCI divider card base
5. Remove 8 screws securing I/O board to system centerplane
6. Remove I/O board from system
7. Transfer SEEPROM module from old I/O board to new I/O board

Install PCI I/O Board
1. Position I/O board in system against centerplane. Use pins on back of I/O board for alignment
2. Replace eight screws securing I/O board to centerplane
   a. Insert top center screw & tighten by 2 turns
   b. Insert screw directly beneath top center screw & tighten by 2 turns
   c. Insert top left & right screws & tighten by 2 turns
   d. Insert remaining screws & tighten by 2 turns
   e. Fully tighten screws in pattern described above
3. Secure PCI card divider base to I/O board with 4 screws
4. Replace back I/O plate on system rear panel
5. Replace hex standoffs securing serial port plate
6. Reconnect cables to I/O board in reverse order to removal

Replace PCI card bracket
1. Position PCI card bracket in system
2. Replace screws securing PCI card bracket to chassis & I/O board stiffener
3. Connect PCI internal status cable (P36) to I/O board at connector J3102
4. Replace 8 PCI card dividers

Replace Fan Trays
Replace RSC Card
Replace PCI Cards
Refit Side Door


OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Boot server and confirm full functionality

PARTS NOTE:

REFERENCE INFORMATION:

V880 http://download.oracle.com/docs/cd/E19095-01/sfv880.srvr/index.html
V890 http://download.oracle.com/docs/cd/E19095-01/sfv890.srvr/index.html