Solution Type  Technical Instruction Sure

Solution  1308640.1 :   How to Replace a Sun Fire X4450 DVD Drive  


Related Items
  • Sun Fire X4450 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X4450 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4450 DVD Drive.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4450 DVD Drive needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the server as described in Powering Off the Server.

2. If the server is in a rack, slide it far enough from the rack so that you can remove the main cover and front cover. If you cannot safely view and access the component, remove the server from the rack.

3. Remove the main cover as described in Removing the Main Cover.

4. Remove the front bezel as described in Removing the Front Bezel.

5. Remove the front cover as described in Removing the Front Cover.

6. Remove the upper cable retainer from the chassis midwall.

7. Disconnect the flex cable connector from the rear of the DVD-ROM drive.

8. Pull the spring latch at the front of the DVD-ROM drive to the left and hold it. Use your other hand to reach behind the drive and push it out through the front of the chassis.

9. Installation is the reverse of this procedure.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.

PARTS NOTE:

REFERENCE INFORMATION:
Sun Fire X4450 Server Service Manual
http://download.oracle.com/docs/cd/E19150-01/

Sun Fire X4150, X4250, and X4450 Servers Diagnostics Guides
http://download.oracle.com/docs/cd/E19150-01/
http://download.oracle.com/docs/cd/E19121-01/



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback