Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1308458.1
Update Date:2017-04-05
Keywords:

Solution Type  Technical Instruction Sure

Solution  1308458.1 :   How to Replace a Power Distribution Board for Sun Fire E2900, v1280 and Netra 1280/1290 Systems:ATR:1047:4  


Related Items
  • Sun Netra 1290 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Oracle Confidential (INTERNAL). Do not distribute to customers
Reason: FRU CAP

Applies to:

Sun Fire E2900 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire V1280 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Netra 1280 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun Netra 1290 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

How to Replace a Power Distribution Board for Sun Fire E2900, v1280 Systems

Solution

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
E2900 Product training or experience in fru replacement procedures of midrange servers.

TASK COMPLEXITY: 4

TIME ESTIMATE: 120 minutes

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW:
Faulty Power Distribution Board

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

* cold swap component complete shutdown required -

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow all ESD precautions.
Take the system to standby mode.
Label and remove all four power cables, IB_SCC connections, and any cables that would impede sliding the chassis from the rack.
Make sure leveling feet are extended to the floor and extend the cabinet stabilizer bar.

Follow the detailed procedure in the E2900 System Server Manual, chapter 13
(http://download.oracle.com/docs/cd/E19095-01/sfe2900.srvr/817-4054-15/817-4054-15.pdf)

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and test functionality. Monitor boot sequence and check prtdiag, fmdump, and dmesg.

REFERENCE INFORMATION:
* Sun Fire v1280/Netra 1280 Manual

http://download.oracle.com/docs/cd/E19095-01/sfv1280.srvr/817-0510-15/817-0510-15.pdf

* Sun Fire E2900 Manual

http://download.oracle.com/docs/cd/E19095-01/sfe2900.srvr/817-4054-15/817-4054-15.pdf