How to Replace a T5120/T5220 and T5140/T5240 Fan Power Board [VCAP]
Related Items |
- Sun SPARC Enterprise T5240 Server
- Sun SPARC Enterprise T5220 Server
- Sun SPARC Enterprise T5120 Server
- Sun SPARC Enterprise T5140 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Sun SPARC Enterprise T5220 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5120 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5140 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5240 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace a Sun SPARC Enterprise T5140/T5240 and T5120/T5220 Fan Power Board
*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1307829.1
*********************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
T5120/T5220 and/or T5140/T5240 product training to be qualified as an Oracle Service personnel
TIME ESTIMATE: 160 minutes
Task Complexity: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: fan board failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1) Remove the Fan Power Board
1. Power off the server.
2. Disconnect the power cables.
3. Extend the server into the maintenance position.
4. Attach an antistatic wrist strap.
5. Remove the top cover.
6. Remove the fan modules.
7. Remove the Phillips screw that secures the fan power board to the chassis.
8. Slide the fan power board to the left to disengage it from the paddle card.
9. Remove the fan power board from the system and place it on an antistatic mat.
2) Install the Fan Power Board
1. Lower the board into its mushroom standoffs in the chassis floor and slide the board to the right into the paddle card.
2. Secure the board to the chassis with a Phillips screw.
3. Install the fan modules.
4. Install the top cover.
5. If the server has been removed from the rack, return it to the rack.
6. Slide the server into the rack.
7. Connect the power cords.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE FE/CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
* If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE:
T5120: https://support.oracle.com/handbook_partner/Systems/SE_T5120/components.html
T5220: https://support.oracle.com/handbook_partner/Systems/SE_T5220/components.html
T5140: https://support.oracle.com/handbook_partner/Systems/SE_T5140/components.html
T5240: https://support.oracle.com/handbook_partner/Systems/SE_T5240/components.html
REFERENCE INFORMATION:
Sun SPARC Enterprise T5120 and T5220 Servers Service Manual - http://download.oracle.com/docs/cd/E19839-01/
Sun SPARC Enterprise T5140 and T5240 Servers Service Manual - http://docs.oracle.com/cd/E19637-01/820-2181-15/820-2181-15.pdf
Save
Save
Attachments
This solution has no attachment