![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1307350.1 : How to Remove and Replace a T5140/T5240 System Board Battery:ATR:1328:0
In this Document
Applies to:Sun SPARC Enterprise T5140 Server - Version All Versions and laterSun SPARC Enterprise T5240 Server - Version All Versions and later Information in this document applies to any platform. GoalHow to remove and replace a T5140/T5240 System Board Battery SolutionDISPATCH INSTRUCTIONS WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure TIME ESTIMATE: 120 minutes Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS: PROBLEM OVERVIEW: System Board Battery Failure WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord.
WHAT ACTIONS ARE REQUIRED?: 1) Remove a Battery 1. Remove PCIe/XAUI riser 2. 2. Using a No. 1 flat-blade screwdriver, press the latch and remove the battery from the motherboard.
2) Install a Battery 1. Unpack the replacement battery. 2. Pry the clip open slightly and insert the battery into the battery holder. 3. Install PCIe/XAUI riser 2. 4. Use the ILOM setdate command to set the day and time. 5. After returning the server to operation, check and reset the Solaris OS date.
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: Verify functionality, no service LEDs or error messages. PARTS NOTE: https://support.oracle.com/handbook_private/Systems/SE_T5140/components.html#Batteries https://support.oracle.com/handbook_private/Systems/SE_T5240/components.html#Batteries
REFERENCE INFORMATION: Sun SPARC Enterprise T5140 and T5240 Servers Service Manual Attachments This solution has no attachment |
||||||||||||||
|