Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1307330.1
Update Date:2017-12-22
Keywords:

Solution Type  Technical Instruction Sure

Solution  1307330.1 :   How to Remove and Replace a T5140/T5240 System Board:ATR:1326:1  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun SPARC Enterprise T5140 Server - Version Not Applicable and later
Sun SPARC Enterprise T5240 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a T5140/T5240 System Board

**************************************************************
To report errors or request improvements on this procedure,
please Add a comment on Doc ID: 1307330.1
**************************************************************

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
T5140/T5240 support training or field experience with other CMT servers.

TIME ESTIMATE: 170 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW:  Replace System Board

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Full verified backups of all data and operating systems potentially affected by service activities. The system needs to be shut down and powered off with power cables disconnected.

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE:
Follow standard ESD precautions. Follow procedures documented in Sun SPARC Enterprise T5140 and T5240 Servers Service Manual
"Servicing the Motherboard Assembly", see the Reference section.

  • When replacing a system board install all FB-DIMMs removed from the old motherboard. Ensure that the FB-DIMM modules are installed in the same memory configuration as they were in before.
  • The SCC module contains system host ID, MAC addresses, and configuration variable settings for ILOM. If you are replacing a system board, you must move the SCC module from the old motherboard to the new one.

NOTE: When replacing motherboard or service processor in LDOM environment, follow the steps and guidelines in Document 1019720.1 to prevent loss of LDOM configuration data and recover LDOM environment after replacement.

NOTE: After replacing the RAID controller (system board), any existing HW RAID volumes (and member disks) may not be seen and need to be recovered (re-activated). If the Disk Volumes (including boot disk/volume) become inaccessible, consult doc ID 1009723.1: Unable to see a pre-existing RAID volume on Sun Fire T1000/T2000, Sun Sparc Enterprise T5120/T5140/T5220/T5240/T5440

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Power on system and observe POST for errors. Boot system and monitor boot sequence for errors. Test functionality of system.
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

Sun Enterprise T5140 https://support.oracle.com/handbook_partner/Systems/SE_T5140/components.html

Sun Enterprise T5240 https://support.oracle.com/handbook_partner/Systems/SE_T5240/components.html

 



REFERENCE INFORMATION:

http://download.oracle.com/docs/cd/E19712-01/
http://download.oracle.com/docs/cd/E19910-01/

References

<NOTE:1009723.1> - Troubleshooting inability to see a pre-existing RAID volume on T1000/T2000 T5120/T5140/T5220/T5240/T5440 T6320/T6340
<NOTE:1019720.1> - How to Replace the Motherboard or Service Processor in a Logical Domain (LDom) Environment
<NOTE:1010457.1> - How to bypass and reset the ALOM password on the V125/V210/V215/V240/V245/V250/V440/V445 and Netra 210/240/440 Servers
<NOTE:1007050.1> - How to Reset ILOM Root Password on T5120/T5220/T5140/T5240 [Video]
<NOTE:1609147.1> - How to recover from lost ILOM 3.0 password on T3/T4/T5, T5x20, T5x40 Servers

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.