![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1307312.1 : How to Remove and Replace a T5140/T5240 Power Supply [VCAP]
In this Document
Applies to:Sun SPARC Enterprise T5140 Server - Version All Versions and laterSun SPARC Enterprise T5240 Server - Version All Versions and later Information in this document applies to any platform. GoalHow to remove and replace a T5140/T5240 Power Suppy (FRU) ************************************************************************************* SolutionDISPATCH INSTRUCTIONS Remove a Power Supply Caution – Hazardous voltages are present. To reduce the risk of electric shock and danger to personal health, follow the instructions. 1. Move to the rear of the server chassis so you can view the power supply status LEDs. The amber Fault LED on the failed power supply will be on. 4. Based on the model of your server (AC or DC), remove power from the server in one of the following ways: Caution – For server models with DC input power, do not disconnect the power cable at the Wago connector on the server DC power supply unit. Instead, turn off the power at the circuit breaker on the power source. 5. Grasp the power supply handle and press the release latch. 6. Pull the power supply out of the chassis.
Install a Power Supply 1. Align the replacement power supply with the empty power supply chassis bay. 2. Slide the power supply into the bay until it is fully seated. 3. Based on the model of your server (AC or DC), apply power to the power supply in one of the following ways: Caution – For server models with DC input power, do not disconnect and reconnect the power cable at the Wago connector on the server DC power supply unit. Instead, control the input power using the circuit breaker at the power source. Verify that the PSU OK LED is lighted. 4. Close the CMA, inserting the end of the CMA into the rear left rail bracket. 5. Verify that the Fault LED on the replaced power supply, the system Power Supply Fault LED, and the front and rear Service Required LEDs are off.
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: Verify Power Supply Functionality, no service LEDs or error messages. https://support.oracle.com/handbook_private/Systems/SE_T5140/components.html#Power https://support.oracle.com/handbook_private/Systems/SE_T5240/components.html#Power
REFERENCE INFORMATION:
Attachments This solution has no attachment |
||||||||||||||
|