Goal
How to remove and replace a T5240 Graphics Card
***************************************************************************************
To report errors or request improvements on this procedure, please Add a Comment on Doc ID: 1307277.1
***************************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED?:No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 45 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS:
PROBLEM OVERVIEW:
Replace Graphics Card
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Full verified backups of all data and operating systems potentially affected by service activities
The system needs to be shut down and powered off with power cables disconnected.
WHAT ACTIONS ARE REQUIRED?:
Follow standard ESD precautions.
Follow procedures documented in Sun SPARC Enterprise T5140 and T5240 Servers Service Manual
"Remove / Install PCIe card"
Remove a PCIe/XAUI card: http://download.oracle.com/docs/cd/E19910-01/E21500-01/z40002fb1405992.html
Install a PCIe/XAUI card: http://download.oracle.com/docs/cd/E19910-01/E21500-01/z40002fb1406214.html
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
* If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.